黄色视频不卡_午夜福利免费观看在线_亚洲国产精品999在线_欧美绝顶高潮抽搐喷水_久久精品成人免费网站_晚上一个人看的免费电影_国产又色又爽无遮挡免费看_成人国产av品久久久

    1. <dd id="lgp98"></dd>
      • <dd id="lgp98"></dd>
        1. | 注冊| 產(chǎn)品展廳| 收藏該商鋪

          行業(yè)產(chǎn)品

          當前位置:
          深圳市浚海中儀科技有限公司>>數(shù)字兆歐表>>鈦淦儀器Tegam>> Megger MJ159 高壓兆歐表

          Megger MJ159 高壓兆歐表

          返回列表頁
          • Megger MJ159 高壓兆歐表
          收藏
          舉報
          參考價 面議
          具體成交價以合同協(xié)議為準
          • 型號
          • 品牌 BS/百試
          • 廠商性質(zhì) 代理商
          • 所在地 深圳市
          在線詢價 收藏產(chǎn)品

          更新時間:2017-11-02 15:45:32瀏覽次數(shù):828

          聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

          同類優(yōu)質(zhì)產(chǎn)品

          更多產(chǎn)品

          產(chǎn)品簡介

          產(chǎn)地類別 進口 類型 數(shù)字式電阻測試儀
          Megger MJ159 高壓兆歐表

          詳細介紹

          The Megger MJ159 Insulation Resistance Tester is part of a series of testers called Major Megger. Major Megger Insulation Resistance Testers are quality crafted, with excellent test voltage regulation, direct measurement readout and an external guard terminal to eliminate surface leakage current from the measurement. Five models are available for general purpose testing which include a low-voltage model.

          All are portable, self-contained instruments designed to give rapid and accurate measurements.

          Four of the models feature an analog display having four selectable test voltages of 100, 250, 500 and 1000 VDC, measuring insulation resistance up to 2000 MΩ, and an ohm range to 5000Ω. The other model has four test voltages of 50, 100, 250 and 500 VDC measuring insulation resistance up to 1000 MΩ.

          The only other difference between the five analog models is the type of power source. Power for models MJ159 and MJ160 is derived from a low-voltage, hand cranked generator which has been designed to be easy to turn even under full load conditions. The low-voltage generator is connected to an electronic inverter to provide a very stable test voltage. Accuracy of measurement is unaffected by variations in the generator cranking speed and the test voltage is maintained at its rated value. Power for model MJ359 is provided by 120 VAC 50/60 Hz or low-voltage generator. Model MJ559 is also 120 VAC 50/60 Hz or internal rechargeable batteries and model MJ459 is powered by 6 replaceable "AA" alkaline cells.

          As a safety feature, the ac voltage range becomes effective as soon as the instrument is connected to the circuit under test. Therefore, a warning is given that the circuit under test is not de-energized before the instrument is operated. Though calibrated for ac voltage, this range also monitors the automatic discharge feature so that after equipment having capacitance (i.e. a cable), has been tested, an indication can be given that the voltage has discharged to a level that is safe for removing the test leads. Each instrument has a guard terminal which may be used to prevent the effects of surface leakage from influencing the readings. This is achieved by diverting the leakage current through the guard terminal and away from the instrument's measuring circuit.

          Each instrument is built into a strong ABS plastic case with a fold down carrying handle.

          Applications for the Major Megger Insulation Resistance Testers

          The Major Meggers have been designed for convenience and ease-of-use when testing complex or larger electrical installations, and commissioning, servicing or maintaining electrical equipment. They are designed for the safe testing of motors, generators. cables, switchgear, transformers, distribution networks, industrial and domestic installations, components and appliances.

          The range of insulation test voltages available allows one instrument to be used for a variety of applications. For example, installations and equipment can be tested at 1000 V d.c. when this requirement is specified, also aircraft and e-communications equipment can be tested at the relatively low 100 V d.c. and 110 V to 120 V a.c. systems can be tested using 250 V d.c.

          Test leads with fused prods are available and it is recommended that these be used when checking that equipment has been isolated from the supply (by performing a voltage test), especially in high energy situations.

          Accessories included with the Megger MJ159 Insulation Resistance Tester:

          • Test lead set (3 leads, 3 prods, 3 clips) 6220-436
          • Test record card (5 supplied) 6172-11
          • Carrying case 6420-111
          • User guide 6172-113

          收藏該商鋪

          登錄 后再收藏

          提示

          您的留言已提交成功!我們將在第一時間回復您~
          二維碼
          金沙县| 昌平区| 芷江| 台湾省| 黄龙县| 巨鹿县| 定日县| 贵州省| 册亨县| 玉山县| 澄城县| 阳高县| 车险| 巴楚县| 苗栗县| 缙云县| 唐山市| 庆城县| 大关县| 兰坪| 微山县| 赤水市| 富锦市| 济宁市| 建阳市| 庆云县| 莲花县| 五大连池市| 湖南省| 通化市| 江川县| 五大连池市| 汽车| 兴安县| 临漳县| 双城市| 敦煌市| 阳朔县| 大安市| 乌拉特中旗| 涿鹿县|