          Introduction 
          Amicon® Ultra-15 10K centrifugal filter devices provide fast ultrafiltration, with the capability for high concentration factors and easy concentrate recovery from dilute and complex sample matrices. The  vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Typical processing time is 15 to 40 minutes. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to  dryness and potential sample loss. The concentrate is collected from the filter device sample reservoir using a pipettor, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging-bucket or fixed-angle rotor. Amicon® Ultra-15 10K devices are supplied non-sterile and are for single use only.
           Intended Use 
          The Amicon® Ultra-15 product line includes 5 different cutoffs (Molecular Weight Cutoff, MWCO), however, the Amicon® Ultra-15 10K device (10,000 MWCO) is the only device intended for in vitro diagnostic use. It can be used to concentrate serum, urine, cerebrospinal fluid, and other body fluids prior to analysis. For information on other Amicon® Ultra-15 cutoffs, go to www.millipore。。com and enter Amicon Ultra-15in the search box.
          Applications 
           ●Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids  (DNA/RNA samples, either single- or double-stranded), microorganisms, column eluates, and  purified samples 
          ●Purification of macromolecular components found in tissue culture extracts and cell lysates, removal of primer, linkers, or molecular labels from a reaction mix, and protein removal prior to HPLC 
          ●Desalting, buffer exchange, or diafiltration 
          Materials Supplied 
          The Amicon® Ultra-15 10K device is supplied with a cap, a filter device, and a centrifuge tube
          Required Equipment  
          ●Centrifuge with swinging-bucket or fixed-angle rotor with wells/carriers that can accommodate  50 mL tubes
          CAUTION: To avoid damage to the device during centrifugation, check clearance before spinning. 
          ●Pipettor with 200 microliter (μL) tip for concentrate recovery 
          Suitability 
          Preliminary recovery and retention studies are suggested to ensure suitability for intended use. See the “How to Quantify Recoveries” section. 
          Shelf Life 
          Shelf life is 3 years from date of manufacture. Refer to expiration date on package label.
          Rinsing Before Use 
          The ultrafiltration membranes in Amicon® Ultra-15 10K devices contain trace amounts of glycerine. If this material interferes with analysis, rinse the device with buffer or Milli-Q® water before use. If interference continues, rinse with 0.1 N NaOH followed by a second spin of buffer or Milli-Q® water.  
          CAUTION: Do not allow the membrane in Amicon® Ultra filter devices to dry out once wet. If you are not  using the device immediay after rinsing, leave fluid on the membrane until the device is used. 
          How to Use Amicon® Ultra-15 Centrifugal Filter Devices 
          1. Add up to 15 mL of sample (12 mL if using a fixed-angle rotor) to the Amicon® Ultra filter device.
          2. Place capped filter device into centrifuge rotor; counterbalance with a similar device. 
          3. When using a swinging-bucket rotor, spin the device at 4,000 × g maximum for approximay 15–40 minutes.When using a fixed-angle rotor, orient the device with the membrane panel facing up and spin at 5,000 × g maximum for approximay 15–40 minutes.NOTE: Refer to Figure 1 and Table 1 for typical spin times. 
          4. To recover the concentrated solute, insert a pipettor into the bottom of the filter device and withdraw the sample using a side-to-side sweeping motion to ensure total recovery. The ultrafiltrate can be stored in the centrifuge tube.
          NOTE: For optimal recovery, remove concentrated sample immediay after centrifugation.
           Desalting or Diafiltration 
          Desalting, buffer exchange, or diafiltration are important methods for removing salts or solvents in solutions containing biomolecules. The removal of salts or the exchange of buffers can be accomplished in the Amicon® Ultra-15 device by concentrating the sample, then reconstituting the concentrate to the original sample volume with any  desired solvent. The process of “washing out” can be repeated until the concentration of the contaminating microsolute has been sufficiently reduced. See example below

          免責(zé)聲明

          • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
          • 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點和對其真實性負責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉(zhuǎn)載時,必須保留本網(wǎng)注明的作品第一來源,并自負版權(quán)等法律責(zé)任。
          • 如涉及作品內(nèi)容、版權(quán)等問題,請在作品發(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
          企業(yè)未開通此功能
          詳詢客服 : 0571-87858618
          临沂市| 平塘县| 江津市| 名山县| 广元市| 台南县| 阿尔山市| 三河市| 丹棱县| 六枝特区| 靖西县| 临夏县| 乡城县| 安多县| 前郭尔| 清丰县| 青海省| 商南县| 太仓市| 芜湖县| 屏东市| 宁武县| 廉江市| 诏安县| 儋州市| 肇东市| 伊宁县| 新乡县| 鹤山市| 右玉县| 汝南县| 石景山区| 紫阳县| 运城市| 磐安县| 肇庆市| 桃园县| 鸡西市| 确山县| 盐津县| 孝昌县|