中國(guó)臺(tái)灣儀鼎 PICOTESY J2100A專業(yè)測(cè)試訊號(hào)轉(zhuǎn)換器
J2100A Injection Transformer 1Hz~5MHz | |
| | | | | | Low band corner frequency 達(dá)1Hz,可支援 功率因數(shù)控制器(PFC)之穩(wěn)定性測(cè)試 | | 5MHz帶寬足以量測(cè)大多數(shù)電源和穩(wěn)壓器 | | 超高頻寬,可達(dá)23 Octave | | 優(yōu)異精確的低失真表現(xiàn) | | 5Ω終端,對(duì)待測(cè)電路的影響降至zui小 | | 包括衰減功能來確保小信號(hào)的測(cè)量正確性 | | 詳細(xì)規(guī)格 | |
| | Product Information | The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes. The usable bandwidth of an injection transformer is generally significantly greater than the 3dB frequency limits. This is because the transformer itself is outside of the measurement, leading many to incorrectly believe that the transformer is a non-critical element. The bandwidth of the transformer is strongly related to the terminating impedance. The most network analyzers provide a 50 Ohm oscillator source impedance. Assuming this impedance the optimal termination resistor is 5 Ohms. This significantly attenuates the injection signal, which is generally beneficial, as a common error in Bode measurements is using a signal which is too large, and therefore not a small signal measurement. An added benefit of this low value is that it can generally be left in circuit at all times, simplifying the connection to the network analyzer without appreciably impacting the output voltage of the circuit being tested. | | Detailed Specifications: | | | Performance at -10dBm input level | Characteristic | Rating | DCR | | Ratio | 1:1 | Termination Impedance | 5 Ohms | Nominal 3dB Bandwidth | 1Hz ~ 5MHz | Isolation Voltage | 600V | Isolation Capacitance | 390pF@1KHz | DC Current | 10mA | Temperature Range | 0 ~ 50°C | Maximum Altitude | 6000 Ft |
|
|
|