您好, 歡迎來(lái)到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海薩帛機(jī)電控制系統(tǒng)有限公司>> MS3470W14-12P接頭Conesys美國(guó)進(jìn)口接頭優(yōu)價(jià),Dr. Thiedig優(yōu)價(jià)DR.FOEDISCH優(yōu)價(jià)
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)MS3470W14-12P接頭
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地上海市
更新時(shí)間:2024-05-15 12:40:42瀏覽次數(shù):1036次
聯(lián)系我時(shí),請(qǐng)告知來(lái)自 化工儀器網(wǎng)上海薩帛機(jī)電設(shè)備有限公司,價(jià)格優(yōu)勢(shì)!
:彭
:(直線) :
詢價(jià)發(fā):sales@sahbore.com、
傳真
地址:中國(guó)(上海)自由貿(mào)易試驗(yàn)區(qū)楊高北路536號(hào)樂(lè)非天地大廈6層
詢價(jià)請(qǐng)?zhí)峁ㄆ放?型號(hào)+數(shù)量+公司全稱/)及圖片信息。我們會(huì)盡快做出回復(fù) 。
優(yōu)價(jià)銷售:
Conesys EUROPE MS3470W14-12P 接頭
|
我司除供應(yīng)Conesys產(chǎn)品外,亦優(yōu)價(jià)銷售如下列表型號(hào):
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
1
Price List for PFM
Dust measuring devices Dr. F?disch Umweltmesstechnik AG
Valid from 01.01.2012 to 31.12.2012
Type of device
List Price / unit
(€)
Particle Flow Meter PFM 92 C*)
*) validated by authorities for continuous dust emission control
according to TA Luft
consisting of:
Measuring probe
Probe length: 100 - 500 mm (standard 300 mm)
(others on request)
Material: stainless steel
Connection: assembly by means of snap closure
Output: 4 ... 20 mA
Limit value switches
4 measuring ranges for an optimum adaptation to the
respective dust concentration range
Power: 24 V DC , 110 VAC or 230 V AC 50 Hz
Manual (English)
1.890,00
Particle Flow Meter PFM 02*)
*) approved as suitability-tested measuring device for the
continuous dust emission control according to TA Luft
consisting of:
probe with integrated display and control unit in the probe’s
head
Probe length: 300 mm (standard)
(others on request)
Material: stainless steel, insulated
Connection: 1"-socket
Output: 4 ... 20 mA
Limit value switches
4 measuring ranges
numerical or graphic presentation on the display
Power: 24 V DC , 110 VAC or 230 V AC
Manual (English)
2.620,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
2
Particle Flow Meter PFM 02 Ex*)
*) approval as measuring device for continuous dust
measurement in area ExII 1/3D IP65 T 74°C
ExII 3G Ex nA IIC T4 consisting of:
probe with integrated display and control unit in the probe’s
head
- length: 300 mm trapezoidal profile (standard)
- Material: stainless steel, insulated
- 2 integrated limit value switches, signal threshold adjustable
- 4 amplification stages for an optimum adaptation to the dust
concentration range
- voltage: 24 V DC
- output: 4...20 mA, potential-separated
3.120,00
filter diagnosis unit PFM 92K
installed in a case
consisting of:
Probe with preamplifier
Probe length: 50 mm up to 500 mm
Material : stainless steel
Connection cable 5 m
Control unit
with serial interface (RS 232)
4 measuring ranges for an optimum adaptation to the
respective dust concentration range
Electronic recorder inside the case
126 mm graphic display with pulldown-menus and quicksetup
3 analog inputs
3 ?" – disc
software ReadWin
Manual (English)
6.100,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
3
Particle Flow Meter PFM 02V*)
*) approved as suitability-tested measuring device for the
continuous dust emission control according to TI Air
with velocity compensation applicable in case of velocity
alterations ?+/- 10%
consisting of:
probe with integrated display and control unit in the probe’s
head
Probe length: 300 mm (standard)
Material: stainless steel, insulated
Connection: 1"-socket
Output: 4 ... 20 mA
Limit value switches
4 measuring ranges
numerical or graphic presentation on the display
analogue input (4…20 mA) for recording a signal in
proportion to the velocity
analogue output (4…20 mA) for the output of the velocity
calculated out of the velocity-proportional signal in the
channel
velocity compensation of the dust signal possible
Power: 24 V DC , 110/230 VAC 50Hz
Manual (English)
6.120,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
4
Flow Measuring Device FMD 02
(suitable for combination with PFM 02 V)
for gas velocities > 3 m/s
- dynamic pressure probe
material: 1.4571
(standard - ) installation length: 500 mm
- Differential pressure transducer 0-10 mbar linear
- weld-in flange 1“
- Signal output 4 ... 20 mA
- voltage supply: 24 V DC, 110/230 VAC 50Hz
2.160,00
Flow Measuring Device FMD 09
approved as measuring deviceaccording to TI Air, 13
th
, 17
th
and
27
th
BImSchV
for measurement of velocity or flow for gas velocities > 5 m/s
consisting of:
Assembly flange with special flange DN 80 PN 6
(standard length 200mm, inner diameter 100 mm
standard material stainless steel)
Dynamic pressure probe
material: 1.4571
(standard) insertion length into the stack: approx. 500 mm
differential pressure transmitter
weld-in flange DN 80 PN 6
ball valves
signal output 4 … 20 mA
for velocity / flow; temperature
voltage supply: 24 V DC, 230 VAC
mounted in a weather protection case (made of GRP)
5.370,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
5
Dust Measuring Device PFM 97 W
consisting of:
Probe
with integrated dust sensors,
differential pressure probe and temperature measurement
?p-transmitter and preamplifier for single signals
Connection cable: 5 m (standard)
dimensions probe head: appr. 250 x 350 x 300 mm
immersion depth: appr. 500 mm (others on request)
Control unit
with integrated LCD-display for visualisation of:
dust concentration, gas velocity and temperature
input-display, automatic measuring range selection
voltage: 230 VAC, 50 Hz ; 24 VDC
output: analogue signals 4...20 mA for:
dust concentration normalised,
dust concentration measured,
calibration signal
6 potential free contacts for signalling of:
measuring modes,
limit value violations and
measuring ranges
dimensions: 240 x 310 x 270 mm
10.170,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
6
Dust Measuring Device PFM 97ED*)
*) validated by authorities for dust concentration measurement
according to TA Luft, 13
th
, 17
th
, 27
thBImSchV
especially for applications in wet and/or sticky gases
consisting of:
Probe unit
sampling probe, immersion depth: 500 mm
(standard length, others on request)
sampling tube heated with flange DN 80 PN 6
injector pump for suck off measuring gas
monitoring of gas flow
triboelectric sensor with electronic unit
plug connections to control unit
weather protection case IP 65
Frame with evaluation unit
Dimensions: 600 x 1700 x 500 mm
Degree of protection: IP 65
Power supply: 3 ~ 400 V / 50 Hz
Fuse: 16 A
equipped and ready for installation wired with:
Evaluation unit
with integrated LCD – Display for display of
dust concentration, gas flow and heating
temperature,
analogue outputs 4-20 mA for dust concentration
and calibration signal
floating contacts for
maintenance,
failure,
limit values and
maintenance request
Voltage and signal distribution
to the control of the beforehand specified devices
2 side channel blowers
for operating the injector pump and supplying dilution
air
27.450,00
Dr. F?disch
Umweltmesstechnik AG
Zwenkauer Stra?e 159, D-04420 Markranst?dt
T. +49-34205-755-0, F. +49-34205-755-40
www.foedisch.de
7
Dust Concentration Measuring Device PFM 06ED
*) validated by authorities for dust concentration measurement
according to TA Luft, 13
th
, 17
th
, 27
thBImSchV
especially for applications in wet and/or sticky gases
Consisting of:
Probe unit
sampling probe at heated tube, total length: 1.000 mm
immersion depth: 800 mm
injector for conveying of measuring gas
flow monitoring
scattered-light sensor
plug connections to the control unit being easy to maintain
weather protection case IP 65
dilution air with heating
Frame with evaluation unit
Dimensions: 600 x 1700 x 500 mm
(W x H x D)
Degree of protection: IP 65 Connection voltage: 3 ~ 400 V / 50 Hz with N and PE
Fuse: 16 A
equipped and wired being ready for installation with:
Evaluation unit
with integrated LCD – Display for display of
dust concentration, flows and heating temperature,
analogue outputs 4-20 mA for dust concentration
and calibration signal aswell as 2 freely-assignable
analogue
outputs (e.g. temperature, flow)
potential-free contacts for maintenance, failure,
limit values and maintenance request
Voltage and signal distribution
for the control of the beforehand specified devices
2 side channel blowers
for the operation of the injector and the supply of dilution air
34.600,00
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。