SMART Current Driver | | KCD2-SCD-Ex1 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.1 %, Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | Current Driver/Repeater | | KFD0-CS-Ex1.51P | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL2 acc. to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field | |
|
| | |
| | | Current Driver/Repeater | | KFD0-CS-Ex2.51P | | | |
|
| | | | | 2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL2 acc. to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field | |
|
| | |
| | | Current Driver | | KFD0-CS-Ex2.53 | | | |
|
| | | | | 2-channel isolated barrier, DC supply (loop powered), Current input/output 0 mA ... 40 mA, Accuracy 1 %, Low voltage drop, Up to SIL2 acc. to IEC 61508, Rated voltage: loop powered, SIL/IEC 61508, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field | |
|
| | |
| | | Current/Voltage Driver | | KFD2-CD-Ex1.32.** | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current or voltage output, Factory configured input/output, Accuracy 0.1 %, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | Current Driver | | KFD2-CD2-Ex2 | | | |
|
| | | | | 2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, I/P and valve positioners, Accuracy 0.05 %, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | SMART Current Driver | | KFD2-SCD-EX1.LK | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Terminals with test points, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | SMART Current Driver | | KFD2-SCD2-Ex1-Y1 | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Lead breakage monitoring, Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | SMART Current Driver | | KFD2-SCD2-Ex1.LK | | | |
|
| | | | | 1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508 | |
|
| | |
| | | SMART Current Driver | | KFD2-SCD2-Ex2.LK | | | |
|
| | | | | 2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 700 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.05 %, Terminals with test points, Up to SIL2 acc. to IEC 61508 |
|
|