YJV 8.7/15KV 3*240電力電纜外徑是多少?
6kV~35kV 中低壓銅芯及鋁芯交聯(lián)聚乙烯絕緣電力電纜(YJV電纜,YJV22電纜,YJLV電纜,YJLV22電纜) XLPE Insulated Power Cable |
YJV 8.7/15KV 3*240電力電纜外徑是多少?交聯(lián)聚乙烯絕緣電力電纜是采用化學(xué)方法或物理方法,使聚乙烯分子由線型分子結(jié)構(gòu)轉(zhuǎn)變?yōu)槿S網(wǎng)狀結(jié)構(gòu),由熱塑性的聚乙烯變成熱固性的交聯(lián)聚乙烯,從而提高了聚乙烯的耐老化性能、機(jī)械性能和耐環(huán)境能力,并保持了優(yōu)良的電氣性能。 /5960111 交聯(lián)聚乙烯絕緣電力電纜導(dǎo)體的允許長(zhǎng)期zui高溫為90攝氏度,較低絕緣電纜、聚氯乙烯絕緣電纜和聚乙烯絕緣電纜高,且具有重量輕、結(jié)構(gòu)簡(jiǎn)單、使用方便、耐化學(xué)腐蝕和敷設(shè)不受落差限制等優(yōu)點(diǎn)。 26/35KV電力電纜,18/30KV交聯(lián)電纜,12/20KVYJV電纜,8.7/15KVYJV22電纜線,6/10KV鋁芯交聯(lián)電纜線,3.6/6KVYJLV單芯電纜 中低壓交聯(lián)電纜產(chǎn)品標(biāo)準(zhǔn) Standard /5960111 本產(chǎn)品按GB12706《額定電壓35V及以下銅芯、鋁芯塑料絕緣電力電纜》標(biāo)準(zhǔn)生產(chǎn),同時(shí)還可根據(jù)用戶需要按電工委員會(huì)推薦標(biāo)準(zhǔn)IEC、英國(guó)標(biāo)準(zhǔn)、德國(guó)標(biāo)準(zhǔn)及美國(guó)標(biāo)準(zhǔn)生產(chǎn)。 The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request. 適用范圍 Applications /5960111 本產(chǎn)品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。 The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv. /5960111 使用特性 Operating characteristics · 工頻額定電壓U0/U為3.6/6kv~26/35kv。 Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. · 電纜導(dǎo)體的zui高允許工作溫度:90℃。 Max.admissible operating temperature of the conductor:90℃. · 短路時(shí)(zui長(zhǎng)時(shí)間不超過5s)電纜導(dǎo)體的zui高溫度不超過2500C。 Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration) /5960111 · 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C。 The ambient temperature under installation should not below 00C. · 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。 The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of a single-core cable should not less than 15 times of the cable diameter. 電纜額定電壓的選擇 Voltage designation · 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/U(Um)kv表示。 U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓; U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓; Um-設(shè)備可承受的“zui高系統(tǒng)電壓"的zui大值。 The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where: U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; U - The rated power-frequency voltage between conductos, for which the cable designed; Um- The maximum value of the“highest system voltage"for which the equipment may beused. · 三相系統(tǒng)用電纜的U0值推薦如下表: The values of U0 recommened for cable to be used in three-phase systems are listed below: |
U kv | U m kv | U 0 * kv | A 和 B 類系統(tǒng) System categories A and B | C 類系統(tǒng) Systems categories C | 6 | 7.2 | 3.6 | 6 | 10 | 12 | 6 | 8.7 | 15 | 17.5 | 8.7 | 12 | 20 | 24 | 12 | 18 | 30 | 36 | 18 | - | 35 | 40.5 | 21 | 26 |
|
A類系統(tǒng)──該類系統(tǒng)任何一相導(dǎo)體與地和接地導(dǎo)體接觸時(shí),能在1min內(nèi)與系統(tǒng)分離 B類系統(tǒng)──該類系統(tǒng)僅包括單相接地故障短時(shí)運(yùn)行的條件,接地故障時(shí)間應(yīng)不超過1h, 但在任何情況下,zui長(zhǎng)不超過8h每年接地故障總持續(xù)時(shí)間不超過125h; C類系統(tǒng)──不屬于A類、B類的系統(tǒng)。 System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. /5960111 System categeory C──This category comprises all systems which do not fall into A and B 電纜的型號(hào)Type of cable |
型號(hào) Type | 名稱 Designation | 適用范圍 Application | YJV | 銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor,XLPE insulated and PVC sheathed power cable | 室內(nèi)、隧道及電纜溝等場(chǎng)所,不能承受機(jī)械外力。單芯電纜不允許敷設(shè)在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible | YJLY | 鋁芯交聯(lián)聚乙烯絕緣乙烯護(hù)套電力電纜 Aluminium conductor, XLPE insulated and PVC sheathed power cable | YJY | 銅芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Copper conductor ,XLPE insulated and PEsheathed power cable | YJLY | 鋁芯交聯(lián)聚乙烯絕緣氯乙烯護(hù)套電力電纜 Alumimium conductor ,XLPE |
|
產(chǎn)品介紹:高壓交聯(lián)電纜產(chǎn)品具有傳輸容量大,工作溫度,不受落差的限制,安裝敷設(shè)方便等特點(diǎn),廣泛應(yīng)用于工礦企業(yè)和城市電網(wǎng)中。高壓交聯(lián)電纜主要用于電力、建筑、工礦、冶金、交通等部門的動(dòng)力、照明輸配電系統(tǒng),由于聚乙烯是電絕緣性能的塑料,加上經(jīng)過高分子交聯(lián)后成為熱固性材料,因此其電性能好,機(jī)械性能和耐熱性好。近二十年來,已成為中國(guó)中、高壓電纜的主導(dǎo)品種,產(chǎn)品適用于6——35KV的各個(gè)電壓級(jí)中它可分為:YJV-交聯(lián)聚乙稀絕緣聚氯乙烯護(hù)套電力電纜,YJV22-交聯(lián)聚乙烯絕緣鋼帶鎧裝高壓電纜,YJLV-交聯(lián)聚乙烯絕緣鋁芯鋼帶鎧裝高壓電纜。
執(zhí)行標(biāo)準(zhǔn):GB/T12706-2002
使用特性
· 工頻額定電壓U0/U為6kv/10kv~26/35kv。
· 電纜導(dǎo)體的zui高允許工作溫度:90℃。
· 短路時(shí)(zui長(zhǎng)時(shí)間不超過5s)電纜導(dǎo)體的zui高溫度不超過2500C。
· 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C。
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
電纜額定電壓的選擇
· 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/U(Um)kv表示。
U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓;
U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓;
Um-設(shè)備可承受的“zui高系統(tǒng)電壓"的zui大值。
產(chǎn)品參數(shù):
導(dǎo)體標(biāo)稱截面 | 絕緣 厚度 | 護(hù)套 厚度 | 電纜近似外徑 | 電纜近似重量 | 20℃ 導(dǎo)體 | 電纜載流量 | 短路電流 |
直流 電阻 | 在空 氣中 | 直埋土壤中 | 導(dǎo) 體 | 屏蔽層 |
銅帶 | 銅絲 |
mm 2 | mm | mm | mm | kg/km | Ω/km | A | A | KA | KA | KA |
3×25 | 3.4 | 2.4 | 48 | 3190 | 0.727 | 120 | 125 | 3.69 | 2.958 | - |
3×35 | 3.4 | 2.5 | 50 | 3731 | 0.524 | 140 | 155 | 5.15 | 2.958 | - |
3×50 | 3.4 | 2.6 | 53 | 4396 | 0.387 | 165 | 180 | 7.31 | 2.958 | - |
3×70 | 3.4 | 2.7 | 57 | 5198 | 0.268 | 210 | 220 | 10.2 | 2.958 | - |
3×95 | 3.4 | 2.9 | 62 | 6350 | 0.193 | 355 | 265 | 13.8 | 2.958 | - |
3×120 | 3.4 | 3 | 65 | 7257 | 0.153 | 290 | 300 | 17.4 | 2.958 | - |
3×150 | 3.4 | 3.1 | 69 | 8383 | 0.124 | 330 | 340 | 21.7 | 2.958 | - |
3×185 | 3.4 | 3.2 | 72 | 9741 | 0.0991 | 375 | 380 | 26.7 | 2.958 | - |
3×240 | 3.4 | 3.3 | 78 | 11854 | 0.0754 | 435 | 435 | 34.6 | 3.301 | - |
3×300 | 3.4 | 3.4 | 84 | 14861 | 0.0601 | 495 | 485 | 43.1 | 3.301 | - |
| | | | | | | | | | |