Indentron 洛氏硬度計
- 公司名稱 昂奇科技(上海)有限公司
- 品牌 Lloyd/英國
- 型號 Indentron
- 產地
- 廠商性質 經(jīng)銷商
- 更新時間 2018/5/14 9:00:00
- 訪問次數(shù) 1588
聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!
Indentron洛氏硬度計特點功能:
垂直方向無阻力測試
主載荷和預載荷均通過砝碼系統(tǒng)施加
自動計時系統(tǒng)剔除對樣品加載時的振動干擾
預載荷監(jiān)控功能
簡單的自校準功能
表面和普通洛氏范圍獨立校準
邊緣絲桿結構臺面無需開孔
Indentron洛氏硬度計參數(shù)
測試標準 ASTM E18
加載 15、30、45、60、100、150(kg)
標尺 HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK、HRL、HRM、HRP、HRR、HRS、HRV
表面洛氏 N、T、W、X、Y
zui大樣品高度 10",15"
彎喉深度 6"
數(shù)據(jù)輸出 RS232(400系列)
可選型號:
標準數(shù)字試驗機
NI-300RD 常規(guī)洛氏普通數(shù)字試驗機
NI-300SRD 表面洛氏普通數(shù)字試驗機
NI-300C 雙洛氏普通數(shù)字試驗機
NI-300RD15 常規(guī)洛氏普通數(shù)字試驗機,15"垂直容量
NI-300SRD15 表面洛氏普通數(shù)字試驗機,15"垂直容量
NI-300C15 雙洛氏普通數(shù)字試驗機,15"垂直容量
高級統(tǒng)計數(shù)字試驗機
NI-400RDS 常規(guī)洛氏高級統(tǒng)計數(shù)字試驗機
NI-400SRDS 表面洛氏高級統(tǒng)計數(shù)字試驗機
NI-400C 雙洛氏高級統(tǒng)計數(shù)字試驗機
NI-400RDS15 常規(guī)洛氏高級統(tǒng)計數(shù)字試驗機,15"垂直容量
NI-400SRDS15 表面洛氏高級統(tǒng)計數(shù)字試驗機,15"垂直容量
NI-400C15 雙洛氏高級統(tǒng)計數(shù)字試驗機,15"垂直容量
注* 400系列不再包括標準時鐘功能
The Indentron® Series hardness testers feature an innovative cantilevered indenter configuration that eliminates frictional inconsistencies typical of competitive testing systems. These systems comply with ASTM E-18. Using precision dead weights, the INDENTRON system ensures precise, accurate and repeatable measurements. The dead weights are used for both the major load and the preload. Automation in the timing, reduces the variation introduced by the flow of the material under load. If the operator inadvertently over loads or under loads the preload, the INDENTRON system prevents the test from being performed.
The indenter design is ideal for testing inside diameters and recesses, often impossible with more traditional hardness testers. Inside diameters as small as 1-1/2-inches can be tested with the standard indenter. Optional indenters can test diameters as small as 1/2-inch. Operators can test close to vertical surfaces, to within 1/4-inch with the standard indenter and up to 3/32-inch with optional special indenters. Testing is fast, accurate and there are fewer broken diamonds due to an outstanding viewing area.
Two models of the Indentron Series are available- the basic 300 Series and the advanced 400 Series. Both models can be supplied for Regular, Superficial or combination testing methods.
The Indentron 400 Series features our advanced digital electronics and display panel. Averaging of 2-99 tests, hardness cale conversion, round correction, minimum thickness, time at load are advanced features supplied standard on the 400 Series. The system can store up to 5000 test results in memory and produce statistical computations. An RS232 output can be used to produce X-Bar/R Charts, histograms or integrate to a personal computer with our DataView application software for more detailed analysis. Tolerances may be applied for Pass/Fail or Go/No Go results.
The Indentron 300 Series uses our basic digital electronics and display panel. Averaging of 2-9 tests with tolerance indication can be achieved. Basic printing of statistics include Average, Range, Min/Max, Standard Deviation, CPK, as wall as the number and percent Hi/Lo based on a user-defined HI/Lo tolerance.
Features & Benefits
- Virtually Friction-Free Operation
The only contact points in the load system are a set of bearings at the end of the lever beam carrying the major load and a leaf spring at the end of the lever beam carrying the minor load. - Dead Weights for Full Load and Preload
Most competitive testers use dead weights for the full load due to their accuracy, but use springs to apply the preload. Dead weights are used on the INDENTRON Series for both full load and preload due to their excellent accuracy and stability under a wide range of conditions. - Full Load Is Applied Precisely at Preload
Automation in the timing reduces the variations introduced by the flow of the material under load. - Preload Error Monitoring
The system prevent the operator for completing a test if the preload is over- or under-applied. ead Weights for Full Load and Preload ead Weights for Full Load and Preload Most competitive testers use dead weights for the full load due to their accuracy, but use springs to apply the preload. Dead weights are used on the INDENTRON Series for both full load and preload due to their excellent accuracy and stability under a wide range of conditions. Automation in the timing reduces the variations introduced by the flow of the material under load. The system prevent the operator for completing a test if the preload is over- or under-applied.
Specifications- Indentron Series | ||
400 Series Regular | 400 Series Superficial | 300 Series Regular | 300 Series Superficial | |
Industry Compliance | ASTM E-18 | ASTM E-18 | ASTM E-18 | ASTM E-18 |
Vertical Capacity | 10” or 15” | 10” or 15” | 10” or 15” | 10” or 15” |
Rockwell Method | Regular | Superficial | Regular | Superficial |
Major Loads (kg) | 60, 100, 150 | 15, 30, 45 | 60, 100, 150 | 15, 30, 45 |
Indenter | C Scale | N Scale | C Scale | N Scale |
Test Block | C, B | 30N, 30T | C, B | 30N, 30T |
Scales | A, B, C, D, F, G | N, T | A, B, C, D, F, G | N, T |
with opt. 1/8" ball | E, H, K | W | E, H, K | W |
with opt. 1/4" ball | L, M, P | X | L, M, P | X |
with opt. 1/2" ball | R, S, V | Y | R, S, V | Y |
MODEL FEATURES | ||||
Hi/Lo Tolerance | Standard | Standard | Standard | Standard |
Scale Conversion | Standard | Standard | - | - |
Roundness Correction | Standard | Standard | - | - |
Adjustable Time @ Load | Standard | Standard | - | - |
Saved Results in Memory | 5000 | 5000 | 5000 | 5000 |
Min. Thickness Calculation | Standard | Standard | - | - |
Software Calibration | Standard | Standard | - | - |
Test Sequence Numbering | Standard | Standard | - | - |
Lot Numbering | Standard | Standard | - | - |
Statistics | ||||
Ave. Test Groups | 2-99 Tests | 2-99 Tests | 2-9 Tests | 2-9 Tests |
Range | Standard | Standard | Standard | Standard |
Min./Max. | Standard | Standard | Standard | Standard |
Standard Deviation | Standard | Standard | Standard | Standard |
CPK | Standard | Standard | Standard | Standard |
No. and % Hi/Lo Tolerance | Standard | Standard | Standard | Standard |
Output | RS232 | RS232 | RS232 | RS232 |